 <title>Measuring AD beam intensity with a Cryogenic Current Comparator </title>
 <link>http://acceleratingnews.web.cern.ch/article/measuring-ad-beam-intensity-cryogenic-current-comparator</link>
 <description>&lt;div class=&quot;field field-name-field-image field-type-image field-label-hidden&quot;&gt;&lt;div class=&quot;field-items&quot;&gt;&lt;div class=&quot;field-item even&quot; rel=&quot;og:image rdfs:seeAlso&quot; resource=&quot;http://acceleratingnews.web.cern.ch/sites/acceleratingnews.web.cern.ch/files/styles/large/public/field/image/4.jpg?itok=XSkXJjbf&quot;&gt;&lt;img typeof=&quot;foaf:Image&quot; class=&quot;img-responsive&quot; src=&quot;http://acceleratingnews.web.cern.ch/sites/acceleratingnews.web.cern.ch/files/styles/large/public/field/image/4.jpg?itok=XSkXJjbf&quot; width=&quot;480&quot; height=&quot;319&quot; alt=&quot;&quot; /&gt;&lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;div class=&quot;field field-name-body field-type-text-with-summary field-label-hidden&quot;&gt;&lt;div class=&quot;field-items&quot;&gt;&lt;div class=&quot;field-item even&quot; property=&quot;content:encoded&quot;&gt;&lt;address&gt;Fig.1: Detail of the PCB holding the CCC coupling circuit and SQUID sensor. (Credit: CERN)&lt;/address&gt;
&lt;p&gt;Non-perturbative measurements of low-intensity charged particle beams are particularly challenging to beam diagnostics due to the low amplitude of the induced electromagnetic fields. However, such measurements are essential to monitor the operation efficiency of Antiproton Decelerator machine and the future extra low energy antiproton rings.  A precise measurement of the beam intensity in the AD is essential to monitor any losses during the deceleration and cooling phases of the AD cycle, and to calibrate the absolute number of particles delivered to the experiments.&lt;/p&gt;
&lt;p&gt;Traditional devices that are able to measure DC beams like the DC Current Transformer (DCCT) are limited in current resolution to ≥ 1 µA. The previously existing Schottky-noise based monitor was very inaccurate when measuring low-intensity DC beams, and intensity measurement using the bunched beam coherent components presented a strong bunch shape and length dependency. In addition, these can not be easily calibrated for an absolute measurement.&lt;/p&gt;
&lt;p&gt;A new beam intensity diagnostic based on a Cryogenic Current Comparator (CCC) was developed for the &lt;u&gt;&lt;a href=&quot;https://home.cern/about/accelerators/antiproton-decelerator&quot;&gt;Antiproton Decelerator (AD)&lt;/a&gt;&lt;/u&gt; machine, which was optimized in terms of its current resolution, system stability and ability to cope with short bunched beams, and immunity to mechanical vibrations. This project was developed in a collaboration between &lt;u&gt;&lt;a href=&quot;https://www.uni-jena.de/en/start.html&quot;&gt;Friedrich Schiller University&lt;/a&gt;&lt;/u&gt;, &lt;u&gt;&lt;a href=&quot;https://www.liverpool.ac.uk/&quot;&gt;University of Liverpool&lt;/a&gt;&lt;/u&gt;, &lt;u&gt;&lt;a href=&quot;https://www.gsi.de/en/start/news.htm&quot;&gt;GSI Helmholtz Centre for Heavy Ion Research&lt;/a&gt;&lt;/u&gt; and &lt;u&gt;&lt;a href=&quot;https://home.cern/&quot;&gt;CERN&lt;/a&gt;&lt;/u&gt;.&lt;/p&gt;
&lt;p&gt;The CCC working principle is based on the measurement of the magnetic ﬁeld induced by the particle beam to be measured. The magnetic ﬂux is concentrated in a high-permeability ferromagnetic pickup core from which it is coupled into the Superconducting Quantum Interference Device (SQUID) sensor via a superconducting ﬂux transformer circuit. A superconducting magnetic shield structure containing the pickup core with a meander structure renders the coupled magnetic ﬁeld nearly independent of the beam transverse position while also shielding the system against external magnetic ﬁeld perturbations. A schematic of the different components is shown below.&lt;/p&gt;
&lt;p&gt;&lt;img src=&quot;/sites/acceleratingnews.web.cern.ch/files/Pictures/issue%2026/art%2011/1.png&quot; style=&quot;border-width: 0px; border-style: solid; width: 1000px; height: 592px;&quot; /&gt;&lt;/p&gt;
&lt;address&gt;Fig.2: Schematic of the CCC, showing the meander-shaped superconducting magnetic shield in grey, the ferromagnetic core in green, the passive magnetic coupling circuit, the SQUID device and its electronic feedback loop read-out. (Credit: CERN)&lt;/address&gt;
&lt;p&gt;The main goal of this project was to demonstrate an operational and stable system that would achieve sub micro-Ampere resolution to be able to measure the coasting and bunched antiproton beams at CERN. Previous systems had already achieved comparable and even superior resolutions of the order of 1nA, however, these were obtained in a laboratory environment and would suffer from significant perturbations from mechanical or EMI noise when installed in an actual accelerator. These could hence not be continuously used during standard machine operation.&lt;/p&gt;
&lt;p&gt;The immunity to mechanical vibrations was accomplished by the delicate and careful design of a new cryostat to house the CCC monitor. This was entirely designed and fabricated at CERN by the Cryogenic Group in the Technology department and the Mechanical and Materials group in the Engineering Department. The geometry of the of the cold-mass support system inside was optimized for reducing the vibration transmission, while at the same time minimizing the heat in-leak to allow for a stand-alone operation with cooling power entirely provided by a cryocooler.&lt;/p&gt;
&lt;p&gt;&lt;img src=&quot;/sites/acceleratingnews.web.cern.ch/files/Pictures/issue%2026/art%2011/2.jpg&quot; style=&quot;border-width: 0px; border-style: solid; width: 596px; height: 528px;&quot; /&gt;&lt;/p&gt;
&lt;address&gt;Fig.3: Cryostat housing CCC monitor. (Credit: CERN)&lt;/address&gt;
&lt;p&gt;The CCC monitor with complete acquisition system was installed in the AD, and has been able to consistently provide a beam current measurement with resolutions down to 2 to 5 nano amperes. Which is equivalent to a beam intensity resolution of 1 to 2.5 x 10&lt;sup&gt;4&lt;/sup&gt; charges at the revolution frequency during injection, and one order of magnitude worse at ejection. This is the ﬁrst operational CCC system able to measure the average current of both bunched and coasting beams in a synchrotron accelerator with an extended autonomy. The cooling of the cryostat with the cryocooler still presents some limitations and after a liquid helium refill the system has been operational for periods of 3 to 5 months.&lt;/p&gt;
&lt;p&gt;&lt;img src=&quot;/sites/acceleratingnews.web.cern.ch/files/Pictures/issue%2026/art%2011/3.jpg&quot; style=&quot;border-width: 0px; border-style: solid; width: 500px; height: 490px;&quot; /&gt;&lt;/p&gt;
&lt;address&gt;Fig.4: Measurement of an AD cycle during beam commissioning, where a low intensity beam was injected and lost at the beginning of the first deceleration ramp. Top-plot: magnetic cycle with beam injection at the beginning of the highest energy plateau; Middle-plot: CCC measurement of the average beam current; Bottom-plot: CCC measurement of the total number of particles and comparison with the measurement obtained from the Schottky noise system. (Credit: CERN)&lt;/address&gt;
&lt;p&gt;The performed measurements represent a considerable improvement over the previously available measurement, making the CCC an important tool for reducing the beam commissioning time, reducing troubleshooting times, and ultimately increasing machine eﬃciency. During the past two year, the monitor has been available for extended periods and the provided intensity measurement has been routinely used by the AD operations team. Another particular improvement is the possibility of absolute calibration of the experiments receiving the particle beam using data from the CCC, as well as cross-calibration of other intensity monitors. Currently going on projects expect to develop and install several CCC monitors in the low-energy &lt;u&gt;&lt;a href=&quot;https://www.gsi.de/work/forschung/appamml/atomphysik/anlagen_und_experimente/cryringesr.htm&quot;&gt;Cryring&lt;/a&gt;&lt;/u&gt; at GSI and several other ones in the &lt;u&gt;&lt;a href=&quot;https://fair-center.eu/&quot;&gt;FAIR&lt;/a&gt;&lt;/u&gt; facility.&lt;/p&gt;
&lt;p&gt;A paper reporting the initial beam measurements performed with the new CCC in the AD with title &lt;u&gt;&lt;a href=&quot;http://iopscience.iop.org/article/10.1088/0953-2048/30/1/015001&quot;&gt;“Non-perturbative measurement of low-intensity charged particle beams”&lt;/a&gt;&lt;/u&gt; was published last year in the Superconductor Science and Technology IOP journal, and has been selected for the journal highlights of that year in the category of Large-Scale Applications together with other 8 papers.&lt;/p&gt;
&lt;p&gt;&lt;img src=&quot;/sites/acceleratingnews.web.cern.ch/files/Pictures/issue%2026/art%2011/5.png&quot; style=&quot;border-width: 0px; border-style: solid; width: 1000px; height: 585px;&quot; /&gt;&lt;/p&gt;
&lt;address&gt;Fig. 5: CCC magnetic superconducting shield and ferromagnetic pickup coil. (Credit: University of Jena)&lt;/address&gt;
&lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;div class=&quot;field field-name-field-tags field-type-taxonomy-term-reference field-label-above&quot;&gt;&lt;div class=&quot;field-label&quot;&gt;Tags:&amp;nbsp;&lt;/div&gt;&lt;div class=&quot;field-items&quot;&gt;&lt;div class=&quot;field-item even&quot; rel=&quot;dc:subject&quot;&gt;&lt;a href=&quot;/tags/antiproton-decelerator&quot; typeof=&quot;skos:Concept&quot; property=&quot;rdfs:label skos:prefLabel&quot; datatype=&quot;&quot;&gt;Antiproton decelerator&lt;/a&gt;&lt;/div&gt;&lt;div class=&quot;field-item odd&quot; rel=&quot;dc:subject&quot;&gt;&lt;a href=&quot;/tags/cryogenic&quot; typeof=&quot;skos:Concept&quot; property=&quot;rdfs:label skos:prefLabel&quot; datatype=&quot;&quot;&gt;cryogenic&lt;/a&gt;&lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;div class=&quot;field field-name-field-date-published field-type-datetime field-label-above&quot;&gt;&lt;div class=&quot;field-label&quot;&gt;Date published:&amp;nbsp;&lt;/div&gt;&lt;div class=&quot;field-items&quot;&gt;&lt;div class=&quot;field-item even&quot;&gt;&lt;span class=&quot;date-display-single&quot; property=&quot;dc:date&quot; datatype=&quot;xsd:dateTime&quot; content=&quot;2018-10-08T00:00:00+02:00&quot;&gt;Monday, October 8, 2018&lt;/span&gt;&lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;div class=&quot;field field-name-field-author field-type-text field-label-above&quot;&gt;&lt;div class=&quot;field-label&quot;&gt;Author:&amp;nbsp;&lt;/div&gt;&lt;div class=&quot;field-items&quot;&gt;&lt;div class=&quot;field-item even&quot;&gt;Miguel Fernandes (University of Liverpool/CERN) &lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;div class=&quot;field field-name-field-article-category field-type-taxonomy-term-reference field-label-above&quot;&gt;&lt;div class=&quot;field-label&quot;&gt;Article Category:&amp;nbsp;&lt;/div&gt;&lt;div class=&quot;field-items&quot;&gt;&lt;div class=&quot;field-item even&quot;&gt;&lt;a href=&quot;/category/acc&quot; typeof=&quot;skos:Concept&quot; property=&quot;rdfs:label skos:prefLabel&quot; datatype=&quot;&quot;&gt;ACC&lt;/a&gt;&lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;div class=&quot;field field-name-field-issue field-type-taxonomy-term-reference field-label-above&quot;&gt;&lt;div class=&quot;field-label&quot;&gt;Issue:&amp;nbsp;&lt;/div&gt;&lt;div class=&quot;field-items&quot;&gt;&lt;div class=&quot;field-item even&quot;&gt;&lt;a href=&quot;/issue/issue-26&quot; typeof=&quot;skos:Concept&quot; property=&quot;rdfs:label skos:prefLabel&quot; datatype=&quot;&quot;&gt;Issue 26&lt;/a&gt;&lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;div class=&quot;field field-name-field-article-description field-type-text-long field-label-above&quot;&gt;&lt;div class=&quot;field-label&quot;&gt;Teaser:&amp;nbsp;&lt;/div&gt;&lt;div class=&quot;field-items&quot;&gt;&lt;div class=&quot;field-item even&quot;&gt;New system can measure the average current of bunched and coasting beams.&lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;ul class=&quot;links list-inline&quot;&gt;&lt;li class=&quot;addtoany first last&quot;&gt;&lt;span&gt;&lt;span class=&quot;a2a_kit a2a_kit_size_32 a2a_target addtoany_list&quot; id=&quot;da2a_1&quot;&gt;
      &lt;a class=&quot;a2a_button_facebook&quot;&gt;&lt;/a&gt;
&lt;a class=&quot;a2a_button_twitter&quot;&gt;&lt;/a&gt;
&lt;a class=&quot;a2a_button_pinterest&quot;&gt;&lt;/a&gt;
      
      
    &lt;/span&gt;
    &lt;script type=&quot;text/javascript&quot;&gt;
&lt;!--//--&gt;&lt;![CDATA[//&gt;&lt;!--
if(window.da2a)da2a.script_load();
//--&gt;&lt;!]]&gt;
&lt;/script&gt;&lt;/span&gt;&lt;/li&gt;
&lt;/ul&gt;</description>
 <pubDate>Mon, 08 Oct 2018 14:00:00 +0000</pubDate>
 <dc:creator>Sabrina El Yacoubi</dc:creator>
 <guid isPermaLink="false">92 at http://acceleratingnews.web.cern.ch</guid>
 <comments>http://acceleratingnews.web.cern.ch/article/measuring-ad-beam-intensity-cryogenic-current-comparator#comments</comments>
</item>
</channel>
</rss>